Connection system
6.2 Signal connection
1FT7 Synchronous Motors
226 Configuration Manual, (PFT7S) 01/2009, 6SN1197-0AD13-0BP2
Cables on motors with DRIVE-CLiQ
With DRIVE-CLiQ, the same cable is used for all encoder types. Only prefabricated cables
from Siemens (MOTION-CONNECT) may be used.
Table 6- 3 Prefabricated cable
6FX 002 - ☐DC☐☐ - ☐☐
0
5 MOTION-
CONNECTⓇ500
8 MOTION-
CONNECTⓇ800
↓↓↓
Length
max. cable length 100 m
max. cable length 50 m
Encoder connection on motors without DRIVE-CLiQ
Motors without DRIVE-CLiQ require a cabinet-mounted sensor module for operation with
SINAMICS S120. The sensor modules evaluate the signals from the connected motor
encoders or external encoders and convert them to DRIVE-CLiQ. In conjunction with motor
encoders, the motor temperature can also be evaluated using sensor modules. For
additional information, refer to the SINAMICS Manual.
(
0
a
6,1$0,&66
'5,9(
&/L4
0RWRU
˽
0RWRU
0RGXOH
3RZHUFDEOH
(QFRGHUFRQQHFWLRQYLD6HQVRU0RGXOH&DELQHW
6HQVRU0RGXOH&DELQHW
6LJQDOFDEOH
Figure 6-4 Encoder interface without DRIVE-CLiQ