Technical data and characteristic curves
4.1 Operating range and characteristics
1FT7 Synchronous Motors
Configuration Manual, (PFT7S) 01/2009, 6SN1197-0AD13-0BP2
79
Effects of the temperature influence and parameter scatter on the characteristic
The torque-speed characteristics specified in the following chapter relate to the nominal
values at operating temperature (shown as characteristic 3 in the chart below).
&RQILJXUHGFKDUDFWHULVWLF)7LVVSHFLILHGZDUPZLWKDYHUDJHYDOXHV
N
(
DQGN
7
XSSHUWROHUDQFHOLPLWQRPLQDOYDOXHFROG
ZLWKILHOGZHDNHQLQJ
ZLWKRXWILHOGZHDNHQLQJ
Q>USP@
0>1P@
N
(
DQGN
7
QRPLQDOYDOXHFROG
N
(
DQGN
7
QRPLQDOYDOXHZDUP
N
(
DQGN
7
ORZHUWROHUDQFHOLPLWQRPLQDOYDOXHZDUP





7\SLFDOVFDWWHU
*XDUDQWHHGWROHUDQFHV
Figure 4-6 Effect of scatter
NOTICE
The motor temperature results in a clear displacement of the voltage limiting characteristic
in the upper speed range. This must be taken into consideration during engineering
(especially for applications in which the cold motor has to produce maximum speeds) with
converter systems without field weakening.

Table of Contents

Other manuals for Siemens 1FT7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens 1FT7 and is the answer not in the manual?

Siemens 1FT7 Specifications

General IconGeneral
BrandSiemens
Model1FT7
CategoryEngine
LanguageEnglish

Related product manuals