Commissioning
8.3 Commissioning using the BOP20 operator panel
SINAMICS DCM DC Converter
278 Operating Instructions, 12/2018, A5E34763375A
〈5.5〉Operation with incremental encoder and SMC30
The actual speed value comes from an incremental encoder connected to
an SMC30 (r3770).
Speed in rpm at 100% speed
The value set here determines the 100% speed for the closed
-loop speed
〈5.6〉Operation with resolver and SMC10
A DRIVE-CLiQ encoder supplies the speed actual value
% speed
The value set here defines the 100
% speed for the closed-loop speed
〈6.1〉Control of the field
Internal field is not used
(e.g. in the case of permanent-magnet motors)
The field is activated with the line contactor
(field pulses are activated or deactivated at the same time as the line
contactor)
-in of the standstill field set using p50257 after a time
that can be parameterized using p50258 has elapsed, once operating state
o7 or higher has been reached
Field current permanently switched on
No speed-dependent or EMF-dependent field weakening
-weakening operation by means of internal closed-loop EMF control,
i.e. at speeds above the motor
's rated speed (= "cut-in speed"), the motor
EMF is constantly kept at setpoint EMFset (r52289) = p50101
– p50100 x
〈7〉Set basic technological functions
System current limit in torque direction I (as % of p50100)
System current limit in torque direction II (as % of p50100)