Operation
9.2 Parameterizing using the BOP20 (Basic Operator Panel 20)
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
373
9.2.2
Displays and using the BOP20
Characteristics
Status display
Changing the active drive object
Displaying/changing parameters
Displaying/acknowledging faults and alarms
Controlling the drive using the BOP20
Status display
The operating display for each drive object can be set using p0005 and p0006. Using the
operating display, you can change into the parameter display or to another drive object. The
following functions are possible:
Changing the active drive object
Press the "FN" and "Arrow up" keys -> the drive object number at the top left flashes
Select the required drive object using the arrow keys
Confirm with the "P" key
Parameter display
Press the "P" key
The required parameter can be selected using the arrow keys
Press the "FN" key -> "r00000" is displayed
Press the "P" key -> returns to the status display