Commissioning
8.7 Commissioning optional additional modules
SINAMICS DCM DC Converter
324 Operating Instructions, 12/2018, A5E34763375A
8.7
Commissioning optional additional modules
Additional modules can be integrated via DRIVE-CLiQ (TM15, TM31, TM150, SMC10,
SMC30) or via the option slot of the Control Unit CUD (CBE20).
The components must be logged in to the firmware during a first commissioning.
That can be done:
Offline by inserting the components into the project in STARTER and loading the project
into the drive
By adding the components through the parameter assignments on BOP20 / AOP30