EasyManua.ls Logo

Siemens CU240S PN-F - Settings of the SS1, SLS and SBC Safety Functions

Siemens CU240S PN-F
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functions
5.12 Safety functions
CU240S and CU240E Control Units, FW 3.2
206 Operating Instructions, 03/2009, A5E02440075B AA
5.12.7 Settings of the SS1, SLS and SBC safety functions
Always parameterize the fail-safe functions using the STARTER PC tool. Parameterizing fail-
safe functions using the BOP is always very time consuming due to the fact that parameters
must be set twice.
The safety functions are parameterized according to the following schematic:
1. Go online with STARTER, open the screen with the safety functions and click on the
button
2. Enable the safety-related parameters by entering the correct password
3. Change the parameters of the safety function
4. Complete parameterization using the button
5. Confirm the checksums of the safety-related parameters
You will find a detailed description of the SS1, SLS and SBC functions in the Function
Manual: (http://support.automation.siemens.com/WW/view/en/31676845
)
Safety function SS1 (Safe Stop 1)
Table 5- 91 Safety-related parameters for SS1
Parameters Description
P9603 = …
P9803 = …
Selecting the signal source of the safety functions
P9680 = …
P9880 = …
Ramp deceleration
You will find a calculation formula for the ramp deceleration in the Function Manual
P9681 = …
P9881 = …
Ramp-down time of the braking ramp
P9682 = …
P9882 = …
Minimum frequency for the standstill detection
P9761 = … Password for the safety functions
P9799 = …
P9899 = …
r9798 = …
r9898 = …
Checksum of the safety-related parameters