Appendix
A.2 Appendix II
BW500 and BW500/L
202 Operating Instructions, 12/2016, A5E33482052-AD
Software Revision
Date
Changes
3.01 July 17, 2001
• Increased maximum idle
time for SmartLinx to 9999
seconds
• Fixed totalizer error when
load is negative and totalizer
drop out is 0.00
• Allowed acces to P635 in
certification mode
• Setting of certification switch
changes totalizer dropout to
0.00
3.02 August 07, 2001
• Fixed bug in totalizer P619
totalizer dropout
3.03 February 20, 2002
• Fixed timing issue with inter-
val printing
• Added % rate and % load to
PID setpoint configuration,
P414
• Updated Auto Zero to allow
run display to be seen, AZ
now flashes in bottom right
hand corner of display
• Updated span adjust calcu-
lation
• Increased totalizer resolution
to 100,000,000
• Improved error interruption
on display
• Fixed zero and span calibra-
tion using remote communi-
cations
3.04 May 09, 2002
• Fixed SmartLinx error check-
ing
• Fixed error with discrete
inputs
• Added P419 PID freeze
enable/disable
• Updated zero calibration
when certification switch set,
now references last operator
initiated zero prior certifica-
tion switch set
• Added power failure indica-
tor on display, "PF"
• Added online calibration