80 |    Part 2   
1)  In case of setting MD14512[11].1 to 0” 
-  Conveyor operation  ; Command M24 
-  Conveyor stop    ; Command M25 
Emergency stop 
Open the front door 
2)  In case of setting MD14512[11].1 to 1” 
-  Conveyor operation    ; Command M24 
-  Conveyor stop    ; Command M25 
Emergency stop 
Open the front door 
After setting time in “Timer Settings” 
 
 
3)  In case that the front door is opened during chip conveyor is operating In case that 
the  front  door  is  opened  during  chip  conveyor  is  operating  by  M24  command, 
conveyor will stop. However, close the front door and press cycle start switch again, 
then  automatic  operation  will  be  continued  and  conveyor  will  start  its  operation 
without  command.  But  in  case  of  pressing  “RESET”  button  on  the  MCP  before 
operation. Chip conveyor will not start without command.