80 | Part 2
1) In case of setting MD14512[11].1 to 0”
- Conveyor operation ; Command M24
- Conveyor stop ; Command M25
Emergency stop
Open the front door
2) In case of setting MD14512[11].1 to 1”
- Conveyor operation ; Command M24
- Conveyor stop ; Command M25
Emergency stop
Open the front door
After setting time in “Timer Settings
3) In case that the front door is opened during chip conveyor is operating In case that
the front door is opened during chip conveyor is operating by M24 command,
conveyor will stop. However, close the front door and press cycle start switch again,
then automatic operation will be continued and conveyor will start its operation
without command. But in case of pressing RESET button on the MCP before
operation. Chip conveyor will not start without command.