54 | Part 2
7.5 Dual chucking (option)
According to the requirement, when chuck is clamped, the pressure can be changed in 2
levels.
(1) Command method
By commanding M-code, the pressure when chuck is clamped or unclamped can be
changed. However, dual chucking operation in different system cannot be executed.
Chucking pressure can
be changed in 2 level,
and changed by M-
code listed below.
M66 ;
Main Chuck
Low pressure
M67 ;
Main chuck
High pressure
Commanded M-code will be finished after time set in machine data listed below elapsed,
and then automatic command can be executed.
MD14510[12] (Setting unit : 100msec)
MD14510[12] is set to 30 (3 sec) if special adjustment isn't required at shipping.
In case of change pressure from high to low, the pressure is not changed instantly after
commanding M-code. Surely unclamp chuck once and clamp chuck, then the pressure
will be changed into low.