30 | Part 2
4.3 Handle feed
Each axes can be traversed by minute step using MPG(Manual Pulse Generator).
(1) How to operate handle
[Handle mode selection]
Press the handle mode selection button.
[Axis selection]
Select the axis to be traversed.
[Traversing axis by rotating MPG in the direction wanted]
As shown in left side figure, The axis will be traversed in +
direction by rotating MPG in + direction, and traversed in -
direction by rotating MPG in - direction.
If the MPG is rotated by a division, the axis will be traversed
in the amount that is decided according to the additional
magnification adjusting switch.
(2) Handle feedrate adjusting
The amount of axis traverse, when the MPG is rotated by one division, is adjusted by
operation the switches shown below.
If each of switches is selected, the lamp in the switch is ON. If the switch is pressed one
more time, then the selection is released and the lamp is OFF.
0.001mm/0.0001inch
in one division
0.01mm/0.001inch in
one division
0.1mm / 0.01inch
in one division