Technical Specifications
5.7Operating Environment
IEEE 802.11n
Maximum Throughput TCP: 80 Mbps at 2.4 GHz
UDP: 100 Mbps at 2.4 GHz
Diversity 2.4 GHz MRC support for extended range
5.0 GHz diversity capable
Host Interface 4-Bit SDIO
Maximum EIRP < 200 mW at 5250 to 5350 MHz
5.7 Operating Environment
The RUGGEDCOM RX1400 is rated to operate under the following environmental
conditions.
Ambient Operating
Temperature
a
b
-40 to 85 °C (-40 to 185 °F)
c
Ambient Storage Tem-
perature
-40 to 85°C (-40 to 185 °F)
Ambient Relative Hu-
midity
d
5% to 95%
Maximum Altitude 2000 m (6562 ft)
Maximum Altitude 2000 m (6562 ft)
a
Ambient Temperature as measured from a 30 cm radius surrounding the center of the enclosure.
b
Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM
SFP Transceivers Catalog for SFP temperature ratings.
c
Maximum ambient operating temperature is 70 °C (158 °F) when the device is installed along with
Underwriter Laboratories (UL) listed devices.
d
Non-condensing
5.8 Mechanical Specifications
Weight 2.5 kg (5.5 lb)
Ingress Protection IP30
Enclosure Aluminum
5.9 Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.