Integrated Blocks and Their Functions S5-100U
DB 30 STL Explanation
0: KH = 0000;
1: KF = +01000;
K PARAMETER (HERE=1), FACTOR 0.001
2: KH = 0000; (VALUE RANGE: - 32768 TO 32767)
3: KF = +01000; R PARAMETER (HERE=1), FACTOR 0.001
4: KH = 0000; (VALUE RANGE: - 32768 TO 32767)
5: KF = +00010; TI=TA/TN (HERE=0.01), FACTOR 0.001
6: KH = 0000; (VALUE RANGE: 0 TO 9999)
7: KF = +00010; TD=TV/TA (HERE=10), FACTOR 1
8: KH = 0000; (VALUE RANGE: 0 TO 999)
9: KF = +00000; SETPOINT W, FACTOR 1
10: KH = 0000; (VALUE RANGE: - 2047 TO 2047)
11: KM = 00000000 00100000; CONTROL WORD
12: KF = +00500; MANUAL VALUE YH, FACTOR 1
13: KH = 0000; (VALUE RANGE: - 2047 TO 2047)
14: KF = +02000; UPPER CONT. LIMIT BGOG, FACTOR 1
15: KH = 0000; (VALUE RANGE: - 2047 TO 2047)
16: KF = -02000; LOWER CONT. LIMIT BGUG, FACTOR 1
17: KH = 0000; (VALUE RANGE: - 2047 TO 2047)
18: KH = 0000;
19: KH = 0000;
20: KH = 0000;
21: KH = 0000;
22: KF = +00000;
ACTUAL VALUE X, FACTOR 1
23: KH = 0000; (VALUE RANGE: - 2047 TO 2047)
24: KF = +00000; DISTURBANCE VARIABLE Z, FACTOR 1
25: KH = 0000; (VALUE RANGE: - 2047 TO 2047)
26: KH = 0000;
27: KH = 0000;
28: KH = 0000;
29: KF = +00000;
FEEDFORWARD XZ FOR DIFF.,
30: KH = 0000; FACTOR 1, (- 2047 TO 2047)
31: KH = 0000;
32: KH = 0000
;
33: KH = 0000;
34: KH = 0000;
35: KH = 0000;
36: KH = 0000;
37: KH = 0000;
38: KH = 0000;
39: KH = 0000;
40: KH = 0000;
41: KH = 0000;
42: KH = 0000;
43: KH = 0000;
44: KH = 0000;
45: KH = 0000;
46: KH = 0000;
47: KH = 0000;
48: KF = +00000;
CONTROLLER OUTPUT Y, FACTOR 1
49: KH = 0000; (VALUE RANGE: - 2047 TO 2047)
50:
9-26
EWA 4NEB 812 6120-02

Table of Contents