Function Modules S5100U
15.6.6 Addressing
The counter module is addressed like an analog module (see section 6.3).
The module may only be plugged into slots 0 to 7.
The address range extends from byte 64 to byte 127.
In both process image tables, eight bytes are reserved per slot and of these eight bytes only the
first four are used.
Slot Addressing
Table 15-6. Slot Addressing
0 1 2 3 4 5 6 7Slot
Address
PII/PIQ
64
to
71
72
to
79
80
to
87
88
to
95
96
to
103
112
to
119
120
to
127
104
to
111
Meaning of the Bytes of a Slot Address (Example: Slot 1)
Table 15-7. Meaning of the Address Bytes of a Slot Address (Example: Slot 1)
Byte
Number
0
1
4 to 7
2
3
Byte
Address
72
73
74
75
76 to 79 Irrelevant
Low
byte
High
byte
Meaning in PIQ
High
byte
Low
byte
Setpoint 1
Setpoint 2
Meaning in PII
Irrelevant
High
byte
Low
byte
Diagnostic byte
Actual value
EWA 4NEB 812 6120-02
15-39