The Integral Real-Time Clock S5-100U
FB13 STL Explanation
NAME :READ CLOCK READING THE CLOCK
DES :WDAY I/Q/D/B/T/C: Q BI/BY/W/D/:BY
DES :DAY I/Q/D/B/T/C: Q BI/BY/W/D/:BY
DES :MON I/Q/D/B/T/C: Q BI/BY/W/D/:BY
DES :YEAR I/Q/D/B/T/C: Q BI/BY/W/D/:BY
DES :HOUR I/Q/D/B/T/C: Q BI/BY/W/D/:BY
DES :AMPM I/Q/D/B/T/C: Q BI/BY/W/D/:BI
DES :MIN I/Q/D/B/T/C: Q BI/BY/W/D/:BY
DES :SEC I/Q/D/B/T/C: Q BI/BY/W/D/:BY
DES :MODE I/Q/D/B/T/C: Q BI/BY/W/D/:BI
:C DB 2
:L DR 0 WEEKDAY
:T =WDAY
:L DL 1 DAY
:T =DAY
:L DR 1 MONTH
:T =MON
:L DL 2 YEAR
:T =YEAR
:L DR 2 HOUR
:L KH 007F ERASE AM/PM BIT
:AW (ONLY RELEVANT IN 12-HOUR MODE)
:T =HOUR
:TB D 2.7 DISPLAY AM/PM BIT
:= =AMPM (ONLY RELEVANT IN 12-HOUR MODE)
:L DL 3 MINUTE
:T =MIN
:L DR 3 SECOND
:T =SEC
:A F 11.1 DISPLAY CLOCK MODE
:= =MODE MODE = 1, IN 12-HOUR MODE
:BE
12-24
EWA 4NEB 812 6120-02

Table of Contents