EasyManua.ls Logo

Siemens SIMATIC CloudConnect CC7 Series - Page 105

Siemens SIMATIC CloudConnect CC7 Series
150 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
4.10 Data points
SIMATIC CC7
Operating Instructions, 10/2019, C79000-G8976-C503-02
105
Trigger
You use the triggers to specify the conditions that initiate the transfer of the value saved in
the device to the broker.
Up to two triggers can be selected per data point. The following trigger classes can be
configured:
Time trigger
Cyclic
Cyclic transmission - configurable cycle
Time
Once daily / Once weekly / Once monthly
Value trigger
Deviation: Transmission in case of deviation from the last stored value
Threshold LOW: Transmission if value is below the threshold
Threshold HIGH: Transmission if value is above the threshold
Range within: Transmission when the value enters a value range
Range outside: Transmission when the value leaves a value range
Input trigger
Digital input
Transfer upon edge change at the digital input
You can combine two triggers for each data point. When two triggers are configured, the
transfer is initiated as soon as one of the two trigger conditions is met.
Not all trigger types can be combined for a tag in practice. The following trigger combinations
are supported:
Permitted trigger combinations
Trigger 1
Trigger 2
Cyclic
Value trigger
Time
-
Value trigger Cyclic
Input trigger
Value trigger
Additional restrictions can result from the trigger types supported by the individual data
types; see "Data types" table below.
Trigger 1 / Trigger 2
The following types of triggers are available: