5
5-2
FM 351 Positioning Function Module
EWA 4NEB 720 6001-02
For configuration it is assumed that you have created a project in which you
can store the parameterization. You will find further information on the con-
figuration of modules in your user manual Standard Software for S7 and M7,
STEP 7. Only the most important steps are explained below.
1. Start the SIMATIC Manager and call the configuration table into your
project.
2. Select a module rack and allocate it.
3. Open the rack.
4. Select the FM 351 Positioning Function Module with the relevant order
number from the module catalog.
5. Drag the FM 351 Positioning Function Module into the appropriate line in
the configuration table.
6. From the configuration table note the input address for the FM 351 Posi-
tioning Function Module, for example 336.
The value which you read out is displayed in decimal format.
Now you can start the parameterization of the FM 351 Positioning Function
Module.
During parameterization you adjust the interface-specific parameters. The
parameterization is carried out with the parameterization software.
1. Double click the order number for the FM 351 Positioning Function Mod-
ule in the configuration table or use the menu command Edit
"
Open ob-
ject....
Result: You enter the dialog field “Basic parameters”.
2. Parameterize the basic parameters for the FM 351 Positioning Function
Module.
3. Click the button “Parameters...”.
Result: You enter the parameterization interface.
4. Parameterize and test the FM 351 Positioning Function Module and save
the entered parameters with File
"
Save to the configuration interface.
5. Terminate the parameterization software.
6. Save your project in the configuration interface.
7. Load the parameterization data with the CPU in the STOP state using
Target system
"
Load
"
Project.
Result: The data is loaded in the CPU memory and is directly transferred
to the FM 351.
8. Execute a CPU start.
Configuration
Parameterization
FM 351 Parameterization