Programming the Technological Functions
6-48
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Table 6-11 User data block (AW-DB), continued
AW-DB FM 353
Bit 0Bit 1Bit 2Bit 3Bit 4Bit 5Bit 6Bit 7Byte
Ready signals
Read
y
signals
Status/checkback signals from POS_CTRL
DBB44 Simulation
Parking
axis
Rotation
monitoring
In-process
measuring
Controller
enable
DBB45
Software
limit posi-
tions dis-
abled
Enable
input dis-
abled
Retrig. ref.
point
Length
measure-
ment
DBB46 Reserved
DBB47
Rescind
setting of
actual va-
lue
Restart
Autom.
block
return
Autom.
block
advance
Delete
residual
distance
Activate
MD
DBB48
Set actual
value
Set refer-
ence point
On-the-fly
MDI block
MDI block
Setpoint for
incremental
dimension
Frequency
levels 1, 2
Speed
levels 1, 2
DBB49 Teach-in
Request
application
data
Program
selection
Digital
outputs
Modify pa-
rameters/
data
Zero offset
On-the-fly
setting
of actual
value
DBB50
to
DBB51
Reserved
DBB52
Data error
read
Operator/
traversing
error read
Operating
error read
Service
data
Actual
value block
change
Next
NC block
Active
NC block
Basic
operating
data
DBB53
Read
measured
values
Application
data
Additional
operating
data
Dig. inputs/
outputs
Parameter/
data

Table of Contents