Configure firmware
2.4 "Advanced" tab
Firmware/BIOS description SIMATIC IPC BX-39A, IPC PX-39A, IPC PX-39A PRO
Operating Instructions, 01/2023, A5E51110693-AA
17
Firmware setting Value Setting in de-
livery state
Meaning
Driver Disable Delay
(only when "Trans-
ceiver Mode" =
"RS485 Half Duplex"
or "Transceiver Mode"
= "RS485/422 Full Du-
plex")
0 bit
The driver disable delay is disabled.
1 bit
x
The driver disable delay is set to one bit length.
2 bits
The driver disable delay is set to two bit lengths.
Select: "Setup Utility (Page 10)" > "Advanced" > "Peripheral Configuration".
Firmware setting Value Setting in de-
livery state
Meaning
IPC BX-39A
IPC PX-39A
IPC PX-39A PRO
Onboard Ethernet 1
(LAN 1, X1 P1)
Disabled
The onboard Ethernet interface "X1 P1" is disabled.
Enabled
x
The onboard Ethernet interface "X1 P1" is enabled.
Onboard Ethernet 2
(LAN 2, X2 P1)
Disabled
The onboard Ethernet interface "X2 P1" is disabled.
Enabled
x
The onboard Ethernet interface "X2 P1" is enabled.
Onboard Ethernet 3
(LAN 3, X3 P1)
Disabled
The onboard Ethernet interface "X3 P1" is disabled.
Enabled
x
The onboard Ethernet interface "X3 P1" is enabled.
Onboard Ethernet 4
(LAN 4, X4 P1)
Disabled
The onboard Ethernet interface "X4 P1" is disabled.
Enabled
x
The onboard Ethernet interface "X4 P1" is enabled.