Configure firmware
2.4 "Advanced" tab
Firmware/BIOS description SIMATIC IPC BX-39A, IPC PX-39A, IPC PX-39A PRO
24 Operating Instructions, 01/2023, A5E51110693-AA
2.4.7 "PCH-FW Configuration"
2.4.7.1 Level: "PCH-FW Configuration"
Note
Depending on the device type and the device configuration, the "PCH
-FW Configuration"
submenu may not be visible.
Calling "PCH-FW Configuration"
Select: "Setup Utility (Page 10)" > "Advanced" > "PCH-FW Configuration".
Firmware setting Value Setting in deliv-
ery state
Meaning
IPC BX-39A
IPC PX-39A
IPC PX-39A PRO
Manageability Fea-
tures State
Disabled
x
The Intel® Manageability functions are disabled.
Enabled
The Intel® Manageability functions are enabled.
AMT BIOS Features
(only if "Managea-
bility Features
State" = Enabled)
Disabled
Intel® Management Engine BIOS Extension (MEBx) is disabled.
Enabled
x
Intel® Management Engine BIOS Extension (MEBx) is enabled and
can be used to configure the Inte Active Management Technol-
ogy (iAMT) hardware.
2.4.7.2 "AMT Configuration"
Level: "AMT Configuration"
Calling "AMT Configuration"
Select: "Setup Utility (Page 10)" > "Advanced" > "PCH-FW Configuration" > "AMT
Configuration".
Firmware setting Value Setting in de-
livery state
Meaning
IPC BX-39A
IPC PX-39A
IPC PX-39A PRO
USB Provisioning of
AMT
Disabled
x
The USB configuration (USB Provisioning) from Intel® Active
Management Technology (iAMT) is disabled.
Enabled
The USB configuration (USB Provisioning) from Intel® Active
Management Technology (iAMT) is enabled.