Complete the user program
4.2 Turn on an output for 5 seconds
Getting started with S7-1200
Getting Started, 11/2009, A5E02486791-01
47
Saving your work in the project
You can now save your work. Simply click the "Save project"
button on the toolbar.
Download and test the Timer instructions
Now you can download your user program. Open the
program editor and simply click the "Download" button.
After connecting to the CPU, STEP 7 Basic displays the "Load preview" dialog. Click
"Load" to download the user program to the CPU. Before clicking "Finish", select "Start all"
to ensure that the CPU goes to RUN mode.
You are now ready to test your program:
1. Ensure that all of the inputs are off.
2. Turn input I0.0 on.
After 5 seconds, the status LED for output Q0.1 turns on.
3. Turn input I0.0 off and turn input I0.1 on.
After 5 seconds, the status LED for output Q0.1 turns off.