Commissioning
5.5 Options of the VLplus heavy-duty bearing system
BA 2030
Operating Instructions, 02/2021, A5E37880173A/RS-AM
63
Setting the lubrication time
CAUTION
Setting the wrong lubrication time
The lubrication time is heavily influenced by the resistance in the lubricant channels and the
ambient temperature.
Check the actual lubrication time during operation.
The actual lubrication time is the time it takes for the lubricator to be completely emptied.
The lubrication time is influenced by the resistance in the lubricant channels and the ambient
temperature.
At an ambient temperature of -10° C, the actual lubrication time is twice that for the set
temperature.
At an ambient temperature of +40° C, the actual lubrication time drops to approximately half
that for the set temperature.
Figure 5-6 Lubrication time controller
Procedure
1. Set the lubrication time with a 3 mm Allen key.
2. Note the date of commissioning and the lubrication time on the lubricator.
The times in months listed in the table are guide values.
Table 5- 2 Timing in months on the lubrication time controller
Size
89
109
129
149
169
Months
12
12
12
12
11