EasyManua.ls Logo

Siemens SIMOGEAR BA 2030

Siemens SIMOGEAR BA 2030
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service and maintenance
8.3 Checking and changing lubricants
BA 2030
88 Operating Instructions, 02/2021, A5E37880173A/RS-AM
8.3.10 Service life of the lubricants
Note
In case of ambient conditions deviating from normal conditions, e.g.
high ambient
temp
eratures, high relative humidity, aggressive ambient media, the intervals between
changes should be shorter. In such cases, contact Technical Support for assistance
in
determining the individual lubricant change interval.
Note
Oil sump temperatures abo
ve +80 °C can reduce service life. A temperature increase by 10 K
halves the service life by the amount as shown in the figure titled "Guide values for oil change
intervals".
For a +80 °C oil sump temperature, the following service life can be expected when observing
the properties specified by Siemens AG:
Table 8- 5 Service life of the oils
Type of oil
Service life
Mineral oil
10 000 operating hours or 2 years
Biodegradable oil
Physiologically safe oil according to USDA-H1/-H2
Synthetic oil
20 000 operating hours or 4 years