Service and maintenance
8.4 Lubrication of the XLplus and VLplus heavy-duty bearing systems
BA 2030
94 Operating Instructions, 02/2021, A5E37880173A/RS-AM
8.4 Lubrication of the XLplus and VLplus heavy-duty bearing systems
The output-side bearing is greased depending on the frame size. Initial greasing has already
been carried out.
In normal operating conditions and with low loads, the lubrication is sufficient for
approximately 25,000 to 30,000 operating hours.
For higher loads due to speed and / or temperature, schedule regreasing at shorter intervals.
Regreasing intervals
rval of the bearing depends on the temperature and the load
For temperatures above +70° C, the regreasing interval must be reduced by half for each
temperature increase of 15
K.
For moderate shock loading and vibration, the regreasing
interval must be reduced by 20%.
For heavy loading, the regreasing interval must be reduced by half.
The regreasing interval is valid for a temperature of +70° C, measured on the surface of the
housing in the vicinity of the bearing.
Regrease the bearing after the following number of operating hours.
Table 8- 7 Regreasing interval in operating hours [h]
Output speed n
2