Service and maintenance
8.5 Replace bearings
BA 2030
96 Operating Instructions, 02/2021, A5E37880173A/RS-AM
Maintenance interval after regreasing
After regreasing, the maintenance interval can be increased to the following number of
operating hours.
Table 8- 9 Maintenance interval in operating hours [h] for relubrication
Output speed n
2
Operating hours for size
89
109
129
149
169
rpm
h
30
80000
80000
80000
80000
50000
31 50
80000
50000
50000
40000
40000
51 100
40000
32000
32000
28000
25000
101 150
28000
28000
25000
25000
20000
151 250
25000
20000
20000
15000
15000
251 400
20000
15000
15000
10000
10000
8.5 Replace bearings
The bearing service life is finite, greatly depends on the operating conditions and therefore
cannot be calculated reliably. In the operating conditions specified by the operator, bearing
life can be calculated. Changes in vibration and noise pattern are an indication that an
immediate bearing replacement is necessary.