8.1 General notes about maintenance work
Gearbox and geared motor in an ATEX design
All measures, checks, and their results must be documented by the operator and
records kept in a safe place for 10 years.
Unintentional starting of the drive unit
Secure the drive unit to prevent it from being started up unintentionally.
Attach a warning notice to the start switch.
Only authorized qualified personnel may perform the maintenance and servicing. Only
original parts supplied by Siemens AG may be installed.
Only qualified personnel may perform the inspection, maintenance and servicing work.
Please observe the General information and safety notes (Page 7).
Table 8- 1 Maintenance measures
Monitor and check the geared
motor for unusual noise,
frequently during operation.
Check the housing temperature.
After 3 hours, on the first day,
thereafter monthly.
Check the bearings for bearing
noise
Regularly every 3000 operating
hours, or at least every
After the first day, and then
every 3,000 operating hours, or
at the latest after 6 months.
lubricants (Page 74)
Check the oil level sensor
Regularly and after oil changes.
Checking the oil level sensor
(optional) (Page 98)
Checking the oil quality
(Page 82)