Service and maintenance
8.1 General notes about maintenance work
BA 2030
72 Operating Instructions, 02/2021, A5E37880173A/RS-AM
Remedy
Interval
Description of work
Change the oil.
Every 2 years or
10,000 operating hours
1)
.
Checking and changing
lubricants (Page 74)
Visual inspection of the
gearbox and shaft sealing ring
for leaks.
After the first day, thereafter
monthly.
Checking the gearbox for leaks
(Page 97)
When required, replace the
breather valve.
Once a year.
Replacing the vent valve
(Page 98)
Clean the gearbox.
Depending on degree of soiling,
at least every 6 months.
Cleaning the gearbox (Page 98)
Carry out a complete inspection
of the geared motor.
Every 12 months.
Inspecting the gearbox
(Page 100)
Check the friction clutch and
adjust if necessary.
After 500 hours, thereafter once
a year and after every blockage.
Observe the BA 2039 Operating
Instructions.
Check the flexible claw coupling.
For the first time after 3 years,
then annually.
Observe the BA 2039 Operating
Instructions.
Check that fastening bolts on
gearboxes and add-on elements
are securely tightened. Check
that covers and plugs are
securely fastened.
After 3 hours, and then every 2
years.
Checking tightness of fastening
bolts (Page 99)
Change the rolling bearing
grease.
When the oil is changed.
Change the roller bearing grease
(Page 87)
Replace the bearing.
-
Replace bearings (Page 96)
Check the rubber buffer of the
torque arms.
Every 6 months.
Torque arms with shaft-
mounted gearboxes (Page 53)
Check the hose of the oil
expansion unit.
Check regularly; renew every 4
years at the latest.
Replacing the hose of the oil
expansion unit (Page 100)
Lubricate the XLplus and VLplus
heavy-duty bearing systems.
-
Lubrication of the XLplus and
VLplus heavy-duty bearing
systems (Page 94)
Check that the paint coating is
undamaged
every 6 months
Surface treatment (Page 20)
Check that the ground
connection is firmly connected
every 6 months
See SIMOTICS XP 1MB1
explosion-protected motors
(
https://support.industry.siemen
s.com/cs/ww/en/view/10975798
1) and SIMOTICS XP 1MB..5/6
explosion-protected motors
(
https://support.industry.siemen
s.com/cs/ww/en/view/10976325
9)
1)
When using synthetic oils, the intervals can be doubled. The data specified is valid for an oil
temperature of +80° C. See the figure titled "Guide values for oil change intervals" for the intervals
for other temperatures.