Faults, causes and remedies
BA 2030
Operating Instructi ons , 02/2021, A5E37880173A/RS-AM
69
not turn when the
Force flow interrupted by breakage in
gearbox.
starts with
difficulty or not at
all.
Incorrect oil level for the mounting
position being used.
Check the mounting position
(Page 115) and the oil level (Page 74).
Incorrect oil being used (e.g. incorrect
viscosity).
Checking the oil quality (Page 82).
Excessive external load on the drive
input and output.
Check the load against rated data (you
might need to correct the belt tension,
Motor brake is not released.
Check circuit / connection of brake.
Check brake for wear and readjust if
Geared motor runs against backstop.
Change the direction of motor or
backstop rotation.
drive input and
output.
Flexible elements worn (e.g. on
couplings).
Replace flexible elements.
Positive connection disrupted by
overload.
Belt tension too low (for belt drive).
Check the belt tension and replace belt
if necessary.