Switching on with the anti-condensation heating active (Page 77)
4.5 Noise emission
Excessive sound pressure levels can lead to hearing impairment or hearing loss.
When assessing the noise level of the system, make due allowance for the noise emissions
from the machine.
If necessary, take suitable noise protection measures for personnel.
4.6 Voltage and frequency fluctuations during line operation
Unless stated otherwise on the rating plate, the permissible voltage fluctuation is ±10 % and
the permissible frequency fluctuation is ±2 % in accordance with range B in IEC / EN 60034-1.
Permissible fluctuations that go beyond this are stamped on the rating plate.
Under operating conditions a machine may sometimes have to be operated outside the limits
of range A.
Exceeding the permissible tolerances for voltage and frequency can lead to an
impermissibly high temperature rise of the winding. This can result in long-term damage to
the machine.
Limit exceptions of this sort with regard to the values that arise, how often, and for how long
they occur.
Where possible and within a reasonable time take corrective actions such as reducing the
power. In this way you can avoid that the service life of the machine is reduced as a result
of thermal aging.
4.7 Phase synchronization during supply system switching
Damage to the machine may be caused when switching to another supply system with different
phasing.
The phasing must be synchronized during switching. Use appropriate means to
synchronize the phasing.
4.8 System-inherent frequencies
Excessively high vibration levels and system resonances can damage the machine set.
Configure and match the system consisting of the foundation and machine set in such a
way that no system resonances can arise and result in the permissible vibration levels being
exceeded.
The vibration values according to DIN ISO 10816-3 must not be exceeded.
Preparations for use
4.5 Noise emission
SIMOTICS HV C 1NB1402-2AA84-4CA0-Z
24 Operating Instructions 06/2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS HV C and is the answer not in the manual?

Siemens SIMOTICS HV C Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS HV C
CategoryEngine
LanguageEnglish

Related product manuals