Thread and fastening parts
Remove the anti-corrosion protection from bolts and tapered pins.
Use the appropriate tap or cutting die to shave the tapped holes of machine parts and
threads of screws, etc. See the drawings for the relevant male and female thread
dimensions.
Use dry compressed air to purge the shaved tapped holes.
Lightly oil the depreserved threads.
Burrs and pressure marks
Check the machine parts, as well as fastening and fixing elements, for burrs or pressure
marks. Use a smoothing file to carefully remove any such burrs/pressure marks.
Only whetstones may be used to smooth finished surfaces.
5.2.8 Setting down the machine
Requirements
The following preconditions must be satisfied before setting down the machine at the
installation location:
The mating faces must be clean.
The anti-corrosion protection paint has been removed from the mating faces, such as the
machine mounting feet, flange, ...
Setting down the machine
Set down the machine slowly and carefully at the installation location to avoid any impact.
Assembly
5.2 Lift the machine to where it will be installed, and position it
SIMOTICS HV C 1NB1402-2AA84-4CA0-Z
Operating Instructions 06/2018 51

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS HV C and is the answer not in the manual?

Siemens SIMOTICS HV C Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS HV C
CategoryEngine
LanguageEnglish

Related product manuals