As such, you can determine whether the machine needs commissioning or any necessary
measures such as cleaning and/or drying the winding:
Can the machine be put into operation?
Must the windings be cleaned or dried?
Detailed information on testing and the limit values can be found here:
"Testing the insulation resistance and polarization index" (Page 41)
8.7 Decommissioning the machine
Record the decommissioning steps. This log will be useful upon recommissioning.
If the machine is going to be out of service for longer than six months, then take the
necessary measures for preservation and storage. Otherwise, the machine could be
damaged as a result of not being operated.
See also
Protection against corrosion (Page 38)
Securing the rotor (Page 31)
Storage (Page 33)
8.8 Re-commissioning the machine
When you re-commission the machine, proceed as follows:
Study the record made when the machine was decommissioned, and reverse the measures
that were taken for conservation and storage.
Perform the measures listed in the "Commissioning" section.
See also
Commissioning (Page 69)
Decommissioning the machine (Page 80)
8.9 Faults
8.9.1 Inspections in the event of faults
Natural disasters or unusual operating conditions, such as overloading or short circuit, are
faults that overload the machine electrically or mechanically.
Operation
8.7 Decommissioning the machine
SIMOTICS HV C 1NB1402-2AA84-4CA0-Z
80 Operating Instructions 06/2018