7.4 Switching on and switching o󹪜
Note
EMERGENCY OFF
To avoid accidents, inform yourself about the EMERGENCY OFF function before you switch on
the system.
The motor is switched on and o󹪜 using the frequency converter.
For more information on this topic, see the chapter in the Operating Instructions for the
converter.
Switching on
Precondition
Ensure that the frequency converter is correctly parameterized.
All safety relays are functional and activated.
Check whether su󹪟cient heat is dissipated from the motor.
Procedure
1. Switch on the motor at the frequency converter.
2. Observe any uneven running and abnormal noise of the motor.
3. Check the function of the safety equipment.
4. Check whether the motor reaches the required parameters
You have switched on the motor.
Switching o󹪜
Switch o󹪜 the motor at the frequency converter.
Commissioning
7.4 Switching on and switching o󹪜
SIMOTICS S-1FK2 synchronous motors for SINAMICS S120
Operating Instructions, 02/2022, A5E46089564B AD 87

Table of Contents

Other manuals for Siemens SIMOTICS S-1FK2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS S-1FK2 and is the answer not in the manual?

Siemens SIMOTICS S-1FK2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS S-1FK2
CategoryEngine
LanguageEnglish

Related product manuals