Quantity structure of DRIVE-CLiQ components
The following maximum number of DRIVE-CLiQ components can be connected to the
SIMOTION D410-2:
Max. 8 Terminal Modules, of these max.
3 TM15, TM17, TM41
8 TM15 DI/DO, TM31, TM120, TM150
1 TM54F
Max. 5 encoder systems
(SMx Sensor Modules or encoders/motors with DRIVE-CLiQ interface)
Max. 1 DMC20/DME20
You require a DRIVE-CLiQ hub module (DMC20/DME20) or a CUA32 to connect more than
one encoder system via DRIVE-CLiQ.