3.3 Mounting the SIMOTION D410-2 on the mounting plate
Overview
Using
a mounting plate, SIMOTION D410-2 can be operated separately, which means it is not
mounted directly on the Power Module.
Application examples:
Offset installation using CUA31/CUA32 Control Unit Adapter (e.g. for reducing the mounting
depth or in order to use additional interfaces on the CUA).
The SIMOTION D410-2 is snapped on to the mounting plate and connected to the Power
Module in blocksize format via DRIVE-CLiQ using CUA31/CUA32. No more than one
Control Unit Adapter can be connected to the SIMOTION D410-2.
Using SIMOTION D410-2 without a Power Module.
A SIMOTION D410-2 mounted on the mounting plate is operated without the Power Module
(e.g. for hydraulic applications).
Requirements
You must order the mounting plate for the SIMOTION D410-2 separately. For the article
number, see Chapter "Spare parts and accessories" in the
SIMOTION D410-2
Manual.
Installing
3.3 Mounting the SIMOTION D410-2 on the mounting plate
SIMOTION D410-2
Commissioning and Hardware Installation Manual, 01/2015 41