Central Braking Modules
The auxiliary voltage is supplied to the Central Braking Modules from the auxiliary voltage supply system. The
following components require auxiliary power:
230 V: Power unit fans
Fuse protection is provided down-circuit of the auxiliary voltage supply system in the Cabinet Module.
Order No. P
150
power
at 400 V / 500 V / 690 V
Current requirement
230 V
50Hz 60 Hz
[kW] [A] [A]
Supply voltage 380 V – 480 V 3AC (DC link voltage 510 V – 720 V)
6SL3700-1AE35-0AA3 500 0.4 0.6
6SL3700-1AE41-0AA3 1000 0.4 0.6
Supply voltage 500 V – 600 V 3AC (DC link voltage 675 V – 900 V)
6SL3700-1AF35-5AA3 550 0.4 0.6
6SL3700-1AF41-1AA3 1050 0.4 0.6
Supply voltage 660 V – 690 V 3 AC (DC link voltage 890 V - 1035 V )
6SL3700-1AH36-3AA3 630 0.4 0.6
6SL3700-1AH41-2AA3 1200 0.4 0.6
Auxiliary Power Supply Modules
The Auxiliary Power Supply Modules themselves generate auxiliary voltages from the line voltage for a S120 Cabinet
Modules configuration and do not therefore require any auxiliary voltage supply.