Drive functions
5.3 Closed-loop velocity control
Hydraulic Drive
System Manual, 04/2015, 6SL3097-4BA00-0BP1
153
The following filters are activated using p1656 and p1657:
Enter the natural frequency for manipulated variable filters 1, 2 (PT2 low-pass) in the
velocity controller.
Enter the damping for manipulated variable filters 1, 2 (PT2 low-pass) in the velocity
controller.
Enter the blocking frequency for control output filters 1, 2 (bandstop) in the velocity
controller.
Enter the -3 dB bandwidth for manipulated variable filters 1, 2 (bandstop) in the velocity
controller.
Enter the numerator bandwidth for control output filters 1, 2 (damped bandstop) in the
velocity controller. Entering a value of 0 initializes the filter as an unattenuated bandstop
filter.