Drive functions 
  5.3 Closed-loop velocity control 
Hydraulic Drive 
System Manual, 04/2015, 6SL3097-4BA00-0BP1 
153 
The following filters are activated using p1656 and p1657: 
●  Enter the natural frequency for manipulated variable filters 1, 2 (PT2 low-pass) in the 
velocity controller. 
●  Enter the damping for manipulated variable filters 1, 2 (PT2 low-pass) in the velocity 
controller. 
●  Enter the blocking frequency for control output filters 1, 2 (bandstop) in the velocity 
controller. 
●  Enter the -3 dB bandwidth for manipulated variable filters 1, 2 (bandstop) in the velocity 
controller. 
●  Enter the numerator bandwidth for control output filters 1, 2 (damped bandstop) in the 
velocity controller. Entering a value of 0 initializes the filter as an unattenuated bandstop 
filter.