Configuration
3.3 Configuring the hydraulics
Hydraulic Drive
System Manual, 04/2015, 6SL3097-4BA00-0BP1
45
The following control and test sequence applies:
Release the
shutoff valve
Step
F-DO +
F-DO -
Diag DO +
Diag DO -
Step
Close the
shutoff valve
1
0
0
0
0
3
2
1
0
1
0
2
3
1
1
1
1
1
The Diag DO signals are checked cyclically by the safety functions in both monitoring
channels. To do so, the HLA module of the Control Unit provides the Diag DO signals via
DRIVE-CLiQ.
The following faults are output in the event of an error:
F01632 SI HLA channel 1: shutoff valve control/feedback signal error
F30632 SI HLA channel 2: shutoff valve control/feedback signal error
The following may be possible causes of a fault:
Shutoff valve either not connected or not correctly connected (X271, X272)
Feedback signal of the shutoff valve either not connected or not correctly connected
(X281, X282)
p9626 (channel 1) or p9826 (channel 2) incorrectly set
Shutoff valve defective
HLA module defective