Commissioning via the built-in BOP
5.5 Quick commissioning
SINAMICS V20 Converter
68 Operating Instructions, 10/2019, A5E34559884-012
Connection macro Cn002 - Control from terminals (PNP/NPN)
External control - Potentiometer with setpoint
Both NPN and PNP can be realized with the same parameters. You can change the
connection of the digital input common terminal to 24 V or 0 V to decide the mode.
Connection macro settings:
Parameter
Description
Factory default
Default for Cn002
Remarks
P0700[0]
Selection of command source
1
2
Terminal as command source
P1000[0] Selection of frequency 1 2 Analog setpoint 1
P0701[0]
Function of digital input 1
0
1
ON/OFF
P0702[0]
Function of digital input 2
0
12
Reverse
P0703[0]
Function of digital input 3
9
9
Fault acknowledgement
P0704[0]
Function of digital input 4
15
10
JOG forward