The individual values involve the users of the logging function, which are assigned
the following functions:
0: Reserved for system functions: simultaneous recording, simulation, synchronized
actions analysis
1: Reserved for system functions: determining program runtimes, multi-step editor
2: Reserved for OEM applications
3: Reserved for OEM applications
4: Reserved for OEM applications
5: Reserved for system functions: trace
6: Reserved for system functions: trace
7: Reserved for system functions: trace
8: Reserved for system functions: trace
9: Reserved for system functions: action log
18371 MM_PROTOC_NUM_ETPD_STD_LIST N02 D1, OEM
- Number of standard data lists ETPD. DWORD PowerOn
-
- 10 25, 6, 0, 0, 0, 25, 25,
25...
25, 6, 0, 0, 0, 25,
25, 25...
25, 25, 25, 25,
25, 25, 25, 25...
1/1
Description: Number of standard data lists in the OPI module ETPD (user-specific).
The individual values involve the users of the logging function, which are assigned
the following functions:
0: Reserved for system functions: simultaneous recording, simulation, synchronized
action analysis
1: Reserved for system functions: determining program runtimes, multi-step editor
2: Reserved for OEM applications
3: Reserved for OEM applications
4: Reserved for OEM applications
5: Reserved for system functions: trace
6: Reserved for system functions: trace
7: Reserved for system functions: trace
8: Reserved for system functions: trace
9: Reserved for system functions: action log
18373 MM_PROTOC_NUM_SERVO_DATA N02 D1
- Number of servo data for log DWORD PowerOn
-
- 10 0, 0, 0, 0, 0, 10, 10, 10... 0 20 1/1
Description: Number of servo data, which must be recordable at the same time (user-specific).
The individual values involve the users of the logging function, which are assigned
the following functions:
0: Reserved for system functions: simultaneous recording, simulation, synchronized
action analysis
1: Reserved for system functions: determining program runtimes, multi-step editor
2: Reserved for OEM applications
3: Reserved for OEM applications
4: Reserved for OEM applications
5: Reserved for system functions: trace
6: Reserved for system functions: trace
7: Reserved for system functions: trace
Machine data
3.2 General machine data
Parameter Manual