8: Reserved for system functions: trace
9: Reserved for system functions: action log
18374 MM_PROTOC_FILE_BUFFER_SIZE N02 -
- Size of log file buffer DWORD PowerOn
-
- 10 15000, 8000, 8000,
8000, 8000, 15000,
15000, 15000...
5000 - 1/1
Description: Size of the data buffer between the IPO and preprocessing time levels of a log file
[ Bytes ].
The individual values involve the users of the logging function, which are assigned
the following functions:
0: Reserved for system functions: simultaneous recording, simulation, synchronized
action analysis
1: Reserved for system functions: determining program runtimes, multi-step editor
2: Reserved for OEM applications
3: Reserved for OEM applications
4: Reserved for OEM applications
5: Reserved for system functions: trace
6: Reserved for system functions: trace
7: Reserved for system functions: trace
8: Reserved for system functions: trace
9: Reserved for system functions: action log
18375 MM_PROTOC_SESS_ENAB_USER N02 -
- Users enabled for sessions BYTE PowerOn
-
- 10 0, 0, 0, 0, 0, 1, 1, 1... 0 1 1/1
Description: Users that are available for session management
The individual values involve the users of the logging function, which are assigned
the following functions:
0: Reserved for system functions: simultaneous recording, simulation, synchronized
action analysis
1: Reserved for system functions: determining program runtimes, multi-step editor
2: Reserved for OEM applications
3: Reserved for OEM applications
4: Reserved for OEM applications
5: Reserved for system functions: trace
6: Reserved for system functions: trace
7: Reserved for system functions: trace
8: Reserved for system functions: trace
9: Reserved for system functions, action log
18601 MM_NUM_GLOBAL_USER_FRAMES N02 K2, M5
- Number of global predefined user frames (SRAM). DWORD PowerOn
-
808d-me42 - 0 0 100 0/0
808d-me62 - 0 0 100 0/0
808d-te42 - 0 0 100 0/0
Machine data
3.2 General machine data
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1 103

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals