Application Releasing the clamping for axes with clamping
Note:
If the clamping
is not released until the travel command is given, these axes
cannot be operated under continuous path control!
Corresponding to ... IS "Traversing key plus" and " ...minus"
for axis 1 in the Work (DB3200 DBX1000.7 and .6 )
for axis 2 in the Work (DB3200 DBX1004.7 and .6 )
for axis 3 in the Work (DB3200 DBX1008.7 and .6 )
Note for the reader Function Manual Basic Functions H1
DB3300
DBX1001.0 to .6
DBX1005.0 to .6
DBX1009.0 to .6
Active machine function 1 INC, ..., continuous
for axis 1 in the Work
for axis 2 in the Work
for axis 3 in the Work
Signal(s) from channel (NCK → PLC)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 The PLC interface receives a signal stating which machine function is active
in the JOG mode for the geometry axes.
Signal state 0 The machine function in question is not active.
Corresponding to ... IS "Machine function 1 INC, ..., continuous"
for axis 1 in the Work (DB3200 DBX1001.0 ... .6)
for axis 2 in the Work (DB3200 DBX1005.0 ... .6)
for axis 3 in the Work (DB3200 DBX1009.0 ... .6)
Note for the reader Function Manual Basic Functions H1
DB3300
DBX4001.1
Workpiece setpoint reached
Signal(s) from channel (NCK → PLC)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 The specified workpiece target has been reached.
Depending on the setting in MD27880 PART_COUNTER:
Bit 1 = 0:for $AC_REQUIRED_PARTS equal to $AC_ACTUAL_PARTS
Bit 1 = 1:for $AC_REQUIRED_PARTS equal to $AC_SPECIAL_PARTS
Signal state 0 The specified workpiece target has not been reached.
Note for the reader Function Manual Basic Functions K1
DB3300
DBX4002.0
ASUB is stopped
Signal(s) from channel (NCK → PLC)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 The signal is set to 1 if the control stops automatically prior to the end of ASUB
(interrupt in a program mode and channel status stopped).
Signal state 0 The IS is set to 0 with start and reset.
Note for the reader Function Manual Basic Functions K1
Detailed descriptions of interface signals
5.7 Channel-specific signals
Parameter Manual