SD 43770 $SA_OSCILL_CTRL_MASK OSCTRL
SD 43780 $SA_OSCILL_IS_ACTIVE OS
The values of D43420 $SA_WORKAREA_LIMIT_PLUS (working area limitation plus) and
SD43430 $SA_WORKAREA_LIMIT_MINUS (working area limitation minus) are to be stored in
the buffered RAM after every RESET, M02, M30 or M17.
--> PROG_SD_RESET_SAVE_TAB[0] = 43420
--> PROG_SD_RESET_SAVE_TAB[1] = 43430
See also: 'REDEF: change attributes of NC language elements', setting data/PRLOC
10712 NC_USER_CODE_CONF_NAME_TAB EXP, N01, N12 TE1, B1
- List of reconfigured NC codes STRING PowerOn
-
- 22 G58, G59, G505, G58,
G506, G59, WAITM,
WAITM
- - 2/2
Description: List of identifiers of the NC codes reconfigured by the user.
The list is to be structured as follows:
Even address: Identifier to be changed
Subsequent odd address: New identifier
The following three types of NC codes can reconfigured:
1. G codes e.g.: G02, G64, ASPLINE...
2. NC addresses e.g.: RND, CHF, ...
3. Pre-defined subprograms e.g.: CONTPRON, ...
10713 M_NO_FCT_STOPRE EXP, N12, N07 H2
- M function with preprocessing stop DWORD PowerOn
-
- 15 -1, -1, -1, -1, -1, -1, -1,
-1...
- - 2/2
Description: The M functions defined by MD10713 $MN_M_NO_FCT_STOPRE perform an implicit
preprocessing stop.
That is, the interpretation of the next part program line will be stopped until the
block with the M function defined in that way has been processed completely
(PLC acknowledgement, motion, etc.).
10714 M_NO_FCT_EOP EXP, N07 K1, H2
- M function for spindle active after reset DWORD PowerOn
-
808d-me42 - 32 - - 1/1
808d-me62 - 32 - - 1/1
808d-te42 - 32 - - 1/1
808d-te62 - 32 - - 1/1
808d-mte40 - -1 - - 2/2
808d-mte60 - -1 - - 2/2
Description: For spindles where a '2' is configured in MD35040 $MA_SPIND_ACTIVE_AFTER_RESET, no
spindle reset is
enabled with this M function when the part program is terminated. The
spindle therefore remains active after the end of the part program.
Proposal: M32
Restrictions: see MD10715 $MN_M_NO_FCT_CYCLE
Related to:
MD35040 $MA_SPIND_ACTIVE_AFTER_RESET
Machine data
3.2 General machine data
Parameter Manual