EasyManuals Logo

Siemens SINUMERIK 808D ADVANCED User Manual

Siemens SINUMERIK 808D ADVANCED
498 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #154 background imageLoading...
Page #154 background image
Machine data
2.3 Channel-specific machine data
Parameter Manual
154
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Description:
1: The last S values set in the main run are still active after a RESET.
This also applies to the dynamic correction values ACC, VELOLIM in spindle
mode.
0: The various S values are equal to 0 after a RESET, and must therefore be
reprogrammed.
The dynamic correction values ACC and VELOLIM are reset to 100% for spindle
mode if the axis-specific MD35040 $MA_SPIND_ACTIVE_AFTER_RESET and MD32320
$MA_DYN_LIMIT_RESET_MASK do not specify anything else.
Note:
The values for ACC and VELOLIM are also retained for spindle mode if MD35040
$MA_SPIND_ACTIVE_AFTER_RESET is not equal to zero or the axis-specific
MD35040 $MA_SPIND_ACTIVE_AFTER_RESET is not equal to zero.
Description: 1: The last programmed F, FA, OVR and OVRA values are still active after
RESET.
This also applies to the dynamic correction values (ACC, VELOLIM, JERKLIM,
ACCLIMA, VELOLIMA, JERKLIMA).
0: The various values are set to their default values after reset.
This does not apply to the dynamic correction values if the axis-specific
MD32320 $MA_DYN_LIMIT_RESET_MASK specifies anything else.
Note:
The dynamic correction values are also retained if the axis-specific MD32320
$MA_DYN_LIMIT_RESET_MASK is not equal to zero.
Related to:
MD22240 $MC_AUXFU_F_SYNC_TYPE Output time of the F functions
Description: Specification of the G code group, the G codes of which are output to the
NCK/PLC interface in case of block change/ reset.
The interface is updated after each block change and reset.
Notice:
It is not guaranteed that a PLC user program has at all times a block-syn-
chronous relation between the active NC block and the G codes present.
Example: Path mode with very short blocks
22400 S_VALUES_ACTIVE_AFTER_RESET C04, C03, C05 -
- S function active beyond RESET BOOLEAN PowerOn
-
- - FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE...
0 - 2/2
22410 F_VALUES_ACTIVE_AFTER_RESET C04, C03, C05 M3,V1
- F function active beyond RESET BOOLEAN PowerOn
-
- - FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE...
0 - 2/2
22510 GCODE_GROUPS_TO_PLC C04 K1,P3 pl,P3 sl
- G codes output at NCK-PLC interface on block change/RESET BYTE PowerOn
-
- 8 2, 0, 0, 0, 0, 0, 0, 0 - - 1/1

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED