Machine data
2.3 Channel-specific machine data
Parameter Manual
154
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Description:
1: The last S values set in the main run are still active after a RESET.
This also applies to the dynamic correction values ACC, VELOLIM in spindle
mode.
0: The various S values are equal to 0 after a RESET, and must therefore be
reprogrammed.
The dynamic correction values ACC and VELOLIM are reset to 100% for spindle
mode if the axis-specific MD35040 $MA_SPIND_ACTIVE_AFTER_RESET and MD32320
$MA_DYN_LIMIT_RESET_MASK do not specify anything else.
Note:
The values for ACC and VELOLIM are also retained for spindle mode if MD35040
$MA_SPIND_ACTIVE_AFTER_RESET is not equal to zero or the axis-specific
MD35040 $MA_SPIND_ACTIVE_AFTER_RESET is not equal to zero.
Description: 1: The last programmed F, FA, OVR and OVRA values are still active after
RESET.
This also applies to the dynamic correction values (ACC, VELOLIM, JERKLIM,
ACCLIMA, VELOLIMA, JERKLIMA).
0: The various values are set to their default values after reset.
This does not apply to the dynamic correction values if the axis-specific
MD32320 $MA_DYN_LIMIT_RESET_MASK specifies anything else.
Note:
The dynamic correction values are also retained if the axis-specific MD32320
$MA_DYN_LIMIT_RESET_MASK is not equal to zero.
Related to:
MD22240 $MC_AUXFU_F_SYNC_TYPE Output time of the F functions
Description: Specification of the G code group, the G codes of which are output to the
NCK/PLC interface in case of block change/ reset.
The interface is updated after each block change and reset.
Notice:
It is not guaranteed that a PLC user program has at all times a block-syn-
chronous relation between the active NC block and the G codes present.
Example: Path mode with very short blocks
22400 S_VALUES_ACTIVE_AFTER_RESET C04, C03, C05 -
- S function active beyond RESET BOOLEAN PowerOn
-
- - FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE...
0 - 2/2
22410 F_VALUES_ACTIVE_AFTER_RESET C04, C03, C05 M3,V1
- F function active beyond RESET BOOLEAN PowerOn
-
- - FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE...
0 - 2/2
22510 GCODE_GROUPS_TO_PLC C04 K1,P3 pl,P3 sl
- G codes output at NCK-PLC interface on block change/RESET BYTE PowerOn
-
- 8 2, 0, 0, 0, 0, 0, 0, 0 - - 1/1