Machine data
2.4 Axis-specific machine data
Description: MD35040 $MA_SPIND_ACTIVE_AFTER_RESET defines the response of the spindle
after channel reset NC/PLC interface signal DB3000 DBX0.7 (Reset) and program
end (M2, M30).
This MD is only active in the spindle mode open-loop control mode. In posi-
tioning mode or oscillation mode, the spindle is always stopped.
MD35040 $MA_SPIND_ACTIVE_AFTER_RESET = 0:
Spindle stops (with M2/M30 and channel and mode group reset).
Program is canceled.
For spindle mode, the programmed ACC and VELOLIM are reset to 100% if
MD22400 $MC_S_VALUES_ACTIVE_AFTER_RESET and the axis-specific MD32320
$MA_DYN_LIMIT_RESET_MASK do not specify anything else.
MD35040 $MA_SPIND_ACTIVE_AFTER_RESET= 1:
Spindle does not stop.
Program is canceled.
For spindle mode, the programmed ACC and VELOLIM are retained.
MD35040 $MA_SPIND_ACTIVE_AFTER_RESET= 2:
Spindle does not stop at the M function configured via MD10714
$MN_M_NO_FCT_EOP (e.g. M32).
However, the spindle stops at channel or mode group reset.
For spindle mode, the programmed ACC and VELOLIM are retained.
The NC/PLC interface signal DB380x DBX2.2 (Delete distance-to-go/Spindle
reset) is always effective, independent of MD35040
$MA_SPIND_ACTIVE_AFTER_RESET.
Not relevant to:
Spindle modes other than open-loop control mode.
Related to:
NC/PLC interface signal DB3000 DBX0.7 (Reset)
NC/PLC interface signal DB380x DBX2.2 (Delete distance-to-go/Spindle reset)
35040 SPIND_ACTIVE_AFTER_RESET A06, A10 S1,Z1,2.7
- Own spindle RESET BYTE PowerOn
CTEQ
-- 2 0 2 1/1