Machine data
2.4 Axis-specific machine data
Parameter Manual
296
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Description:
GANTRY_BREAK_UP = "0"
The forced coupling of the gantry axis grouping remains valid! Monitoring of
violation of the gantry warning or trip limit is active!
GANTRY_BREAK_UP = "1"
This breaks up the forced coupling of the gantry grouping, thus allowing all
gantry axes in this grouping to be traversed individually in JOG, AUTOMATIC,
and MDI modes. Monitoring for violation of the gantry warning or trip limit
is deactivated! The NC/PLC interface signal DB390x DBX5005.5 "gantry grouping
is synchronized" is set to "0".
Notice:
In cases where the gantry axes continue to be mechanically coupled, the
machine may sustain damage in this operating state when the leading or syn-
chronized axis is traversed!
The gantry axes cannot be referenced individually.
Corresponds with:
MD 37100: $MA_GANTRY_AXIS_TYPE Gantry axis definition
MD 37110: $MA_GANTRY_POS_TOL_WARNING Gantry warning limit
MD 37130: $MA_GANTRY_POS_TOL_REF
Gantry trip limit during referencing
NC/PLC interface signal DB390x DBX5005.5 (gantry grouping is synchronized)
NC/PLC interface signal DB390x DBX5005.2 (gantry trip limit exceeded)
37140 GANTRY_BREAK_UP EXP, A01, A10 G1,Z3
- Invalidate gantry axis grouping BOOLEAN Reset
CTEQ
808d-me42 - FALSE 0 - -1/2
808d-me62 - FALSE 0 - 1/1
808d-te42 - FALSE 0 - -1/2
808d-te62 - FALSE 0 - 1/1