Detailed descriptions of interface signals
4.7 Channel-specific signals
Signal state 1 The dry run feedrate is active.
Instead of the programmed feedrate, the dry run feedrate entered in setting
data:
SD42100 $SC_DRY_RUN_FEED
is active.
When activated from the operator panel, the dry run feedrate signal is
automatically entered in the PLC interface and transmitted by the PLC basic
program to the PLC interface signal:
DB3200 DBX0.6 (activate dry run feedrate).
Signal state 0 Dry run feedrate is not active. The programmed feedrate is active.
Note for the reader Function Manual Basic Functions K1
DB3300
DBB4004
PROG-EVENT-DISPLAY
Signal(s) from channel (NCK → PLC)
Edge evaluation: No Signal(s) updated: Event-controlled
Signal state 1 The event assigned to the bit has activated the "Event-driven program call"
function:
Bit 0 → Part program start from channel status RESET
Bit 1 → End of part program
Bit 2 → Operator panel reset
Bit 3 → Boot
Bit 4 → 1st start after search run
Bit 5 - 7 → Reserved, currently always 0
Signal duration: At least one complete PLC cycle
Signal state 0
• The event assigned to the bit has not activated the "Event-driven
program call" function.
• The event-driven user program has expired or was cancelled with
RESET.
Note for the reader
DB3300
DBX4006.0
ASUB active
Signal(s) from channel (NCK → PLC)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 One ASUB is active.
Signal state 0 No ASUB is active.
Note for the reader Function Manual Basic Functions K1
DB3300
DBX4006.0
ASUB active
Signal(s) from channel (NCK → PLC)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 An ASUB with suppressed display update is active (refer to MD20191).
Signal state 0 No ASUB with suppressed display update is active.
corresponding to ... MD20191 IGN_PROG_STATE_ASUP
(do not display execution of the interrupt program on the OPI)
Note for the reader Function Manual Basic Functions K1
Siemens Controls

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals