EasyManua.ls Logo

Siemens SINUMERIK 808D ADVANCED - Page 404

Siemens SINUMERIK 808D ADVANCED
498 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Detailed descriptions of interface signals
4.8 Axis / spindle-specific signals
Parameter Manual
404
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
corresponding to ... DB380x DBX2.1 (controller enable)
DB390x DBX1.5 (position controller active)
MD30350 SIMU_AX_VDI_OUTPUT
(output of axis signals for simulation axes)
Note for the reader Function Manual Basic Functions S1
DB390x
DBX1.7
Current controller active
Signal(s) from axis / spindle (NCK PLC)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 The control signals that the current controller is closed.
Signal state 0 The control signals that the current controller is open. The current controller
output (including the feedforward quantities on the manipulated variable for
the voltage) is cleared.
corresponding to ... DB390x DBX1.5 (position controller active)
DB390x DBX1.6 (speed controller active)
Note for the reader Function Manual Basic Functions S1
DB390x
DBX2.1
Handwheel override active
Signal(s) from axis / spindle (NCK PLC)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 The function "Handwheel override in Automatic mode" is active for the
programmed positioning axis (FDA[AXi]). Handwheel pulses for this axis
affect the programmed axis feedrate either as path definition (FDA = 0) or
as velocity override (FDA > 0).
Signal state 0 The function "Handwheel override in Automatic mode" is not active for the
programmed positioning axis (or concurrent positioning axis).
An active handwheel override is not active if:
The positioning axis has reached the target position.
The distance-to-go is deleted by the axis-specific interface signal
DB3200 DBX6.2 (delete distance to go).
A RESET is performed.
Note for the reader Function Manual, Expansion Functions H1