Machine data
2.2 General machine data
Parameter Manual
44
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Description:
The machine data contains the name of the cycle. This cycle is called if the
M function has been programmed from MD10715 $MN_M_NO_FCT_CYCLE.
If the M function is programmed in a motion block, the cycle is executed
after the motion.
MD10715 $MN_M_NO_FCT_CYCLE is active in both Siemens mode G290 and in exter-
nal language mode G291.
If a T number is programmed in the call block, then the programmed T number
can be polled in the cycle under the variable $P_TOOL.
M and T function replacements must not be programmed simultaneously in one
block. This means that not more than one M or T function replacement may be
active in any one block.
Neither an M98 nor a modal subprogram call may be programmed in a block with
M function replacement.
Moreover, neither subprogram return nor part program end are allowed.
Alarm 14016 is issued if there is a conflict.
Related to:
MD10715 $MN_M_NO_FCT_CYCLE,
MD10717 $MN_T_NO_FCT_CYCLE_NAME
Description: Cycle name for tool change routine on call-up with a T function.
If a T function is programmed in a part program block, the subprogram defined
in T_NO_FCT_CYCLE_NAME is called at the end of the block.
The T number programmed can be polled in the cycle via system variables $C_T
/ $C_T_PROG as a decimal value and via $C_TS / $C_TS_PROG as a string (only
with tool management). MD10717 $MN_T_NO_FCT_CYCLE_NAME is active both in Sie-
mens mode G290 and in external language mode G291.
MD10716 $MN_M_NO_FCT_CYCLE_NAME and MD10717 $MN_T_NO_FCT_CYCLE_NAME must not
be active in one block at the same time, i.e. no more than one M/T function
replacement can be active per block. Neither an M98 nor a modal subprogram
call can be programmed in a block with a T function replacement. Furthermore,
neither subprogram return nor part program end are allowed.
Alarm 14016 is output in the event of a conflict.
Related to:
MD10715 $MN_M_NO_FCT_CYCLE,
MD10716 $MN_M_NO_FCT_CYCLE_NAME
10716 M_NO_FCT_CYCLE_NAME EXP, N12, N07 K1
- Subroutine name for M function replacement STRING PowerOn
-
- 30 ... - - 2/2
10717 T_NO_FCT_CYCLE_NAME EXP, N12, N07 K1
- Name of tool-changing cycle for T function replacement STRING PowerOn
-
- - - - 2/2