Machine data
2.2 General machine data
Parameter Manual
78
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Description:
For PROFIBUS/PROFINET only:
The trigger frequency is configured bit-by-bit
Bits 0-15: 0x0001-0xffff: bit mask
Bits 16-23: 0x01-0x14: process data number (a maximum of 20 words are permis-
sible)
Bits 24-27:0x01: status change 0->1
0x00: status change 1->0
Bits 28-31:0x10: send slot
0x00: receive slot
When MD13113 $MN_PROFIBUS_TRACE_START=1 and MD13114
$MN_PROFIBUS_TRACE_START_EVENT=0x0 Recording starts immediately
When MD13113 $MN_PROFIBUS_TRACE_START=1 and MD13114
$MN_PROFIBUS_TRACE_START_EVENT=0x1 Recording starts on control power on
When MD13113 $MN_PROFIBUS_TRACE_START=1 and MD13114
$MN_PROFIBUS_TRACE_START_EVENT=0x2 Recording starts on loss of the sign of
life
Description: This MD defines the electrical polarity of each connected sensor.
Value 0:
(Default setting)
Non-deflected state 0 V
Deflected state 24 V
Value 1:
Non-deflected state 24 V
Deflected state 0 V
The programmed edges of the sensor are independent of the electrical polar-
ity, and are to be regarded as purely mechanical. The programming of a posi-
tive edge always means the transition from the non-deflected into the
deflected state. The programming of a negative edge always means the transi-
tion from the deflected into the non-deflected state.
13114 PROFIBUS_TRACE_START_EVENT EXP -
- Trigger conditions for PROFIBUS/PROFINET trace DWORD NEW CONF
-
808d-me42 14 0, 0, 0, 0, 0, 0, 0, 0... 0x00000000 0x111fffff 0/0
808d-me62 14 0, 0, 0, 0, 0, 0, 0, 0... 0x00000000 0x111fffff 1/1
808d-te42 14 0, 0, 0, 0, 0, 0, 0, 0... 0x00000000 0x111fffff 0/0
808d-te62 14 0, 0, 0, 0, 0, 0, 0, 0... 0x00000000 0x111fffff 1/1
13200 MEAS_PROBE_LOW_ACTIVE N10, N09 M5
- Polarity reversal of sensor BOOLEAN PowerOn
-
- 2 FALSE, FALSE 0 - 3/3