EasyManua.ls Logo

Siemens SINUMERIK 828D PPU Series - Page 102

Siemens SINUMERIK 828D PPU Series
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Optional customer buttons OUT (X53 / X54)
The short-circuit-proof outputs X53/X54 are provided to control lamps in the buttons. Lamps
with 24 V and 1.2 W per output are recommended.
;
0
0
3
.7287
.7287
.7287
;
0
0
3
.7287
.7287
.7287
Figure 7-7 Main circuit diagram for input circuit for X53 and X54
CAUTION
Do not connect any relays, valves or other inductive loads.
Connector designation: X53, X54
Connector type: 4-pin plug connector
Table 7-6 Assignment of connector X53
Pin Signal name Signal type Meaning
1 KT-OUT1
O
Output 1 lamp
2 KT- OUT2 Output 2 lamp
3 KT- OUT3 Output 3 lamp
4 M V Ground
Table 7-7 Assignment of connector X54
Pin Signal name Signal type Meaning
1 KT-OUT4
O
Output 4 lamp
2 KT- OUT5 Output 5 lamp
3 KT- OUT6 Output 6 lamp
4 M V Ground
Connectable components
7.1 MCP 483C PN
PPU
102 Manual, 01/2014, 6FC5397-2DP40-3BA3

Table of Contents