Figure 9-3 Principal mode of operation of the PN/PN coupler (example)
References
SIMATIC bus couplings PN/PN coupler Hardware Installation and Operating Manual
9.2.2 Configuration
Requirements
Please observe the following preconditions when configuring:
For SINUMERIK 828D, the "PN-PN-Coupler20" name is already permanently defined; as
a consequence, the name must be exactly the same in the connected subnet.
The PN/PN coupler has the IP address 192.168.214.20 (permanently set).
The I/O address area is 16 bytes from 96 ...111 (index m).
SINUMERIK 828D must be connected to the PROFINET interface X1.
Spare parts and accessories